MAY 1995
ME657A-F ME657A-M
ME658A-F ME658A-M
ME659A-F ME659A-M
Multi-Function Line Drivers
Multi-Function
Line Driver
CUSTOMER
SUPPORT
INFORMATION
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com • E-mail: [email protected]
Zobrazit stránku 0
1 2 3 4 5 6 ... 33 34

Shrnutí obsahu

Strany 1 - Multi-Function Line Drivers

MAY 1995ME657A-F ME657A-MME658A-F ME658A-MME659A-F ME659A-MMulti-Function Line DriversMulti-FunctionLine DriverCUSTOMERSUPPORTINFORMATIONOrder toll-fr

Strany 2 - INDUSTRY CANADA

5CHAPTER 3: Configuration This chapter describes the locations and posssible settings of the Multi-Function Line Driver’s DIP configuration switches,

Strany 3 - INSTRUCCIONES DE SEGURIDAD

6MULTI-FUNCTION LINE DRIVER3.2 Configuration Switch “SW1”Use the individual positions on DIP switch SW1 to set data rate, clock source,sync vs. async

Strany 4 - NOM STATEMENT

7SW1 Positions 1 through 4: Data-Rate SettingSet positions 1 through 4 of switch S1 to determine the data rate (valid forboth synchronous and asynchro

Strany 5 - Contents

8MULTI-FUNCTION LINE DRIVERSW1 Position 8: Carrier-Control MethodSet position 8 of switch SW1 to determine whether the carrier is “constantlyon” or “c

Strany 6 - 1. Specifications

9SW2 Positions 1 and 2: Word LengthSet positions 1 and 2 of switch SW2 to determine the word length that theMulti-Function Line Driver will expect for

Strany 7

10MULTI-FUNCTION LINE DRIVERSW2 Positions 6 and 7: 2-Wire vs. 4-Wire OperationSet position 6 of switch SW2 to determine whether the Multi-Function Lin

Strany 8 - CHAPTER 1: Specifications

11CHAPTER 4: Installation Once the Multi-Function Line Driver is properly configured, you can connectit to your system. This chapter describes how to

Strany 9 - 2. Introduction

12MULTI-FUNCTION LINE DRIVER4.1.1 MODEM-TO-MODEMCABLING FOR THEME657 MODELSIf your application requires that you run a pair or two of bare wires betwe

Strany 10 - 3. Configuration

133. Strip the insulation on back about a quarter of an inch (0.6 cm) fromthe ends of the twisted-pair wires, as shown below for a four-wire cable:4A.

Strany 11 - 12345678

14MULTI-FUNCTION LINE DRIVER6. When you finish connecting the wires to the terminal block, the assemblyshould look something like this (four-wire inst

Strany 12 - CHAPTER 3: Configuration

FEDERAL COMMUNICATIONS COMMISSIONANDINDUSTRY CANADARADIO FREQUENCY INTERFERENCE STATEMENTSThis equipment generates, uses, and can radiate radio freque

Strany 13 - 3.3 Configuration Switch “S2”

158. Insert the strain-relief assembly with the wire going through it into theslot in the bottom of the modem case, and set it into the recess of thec

Strany 14

16MULTI-FUNCTION LINE DRIVER4.1.2 MODEM-TO-MODEMCABLING FOR THEME658 ANDME659 MODELSIf your application requires that you run cables with RJ-11 or RJ-

Strany 15

17Table 4-1. Line-Cable PinoutsRJ-11 (Four-Wire)SIGNAL PIN# COLOR* COLOR* PIN# SIGNALGND** 1 Blue...Whi

Strany 16 - 4. Installation

18MULTI-FUNCTION LINE DRIVER4.2 RS-232 Serial ConnectionsThe Multi-Function Line Driver’s RS-232 port is a standard DB25 connector(pinout shown in Tab

Strany 17

19CHAPTER 4: Installation 4.2.2 CONNECTING THEMFLD TO ADCE DEVICEBecause the Multi-Function Line Driver is wired as a DCE device, you can’tplug it dir

Strany 18 - CHAPTER 4: Installation

20MULTI-FUNCTION LINE DRIVEROnce you have configured each Multi-Function Line Driver and connectedthe cables, you are ready to operate the units. They

Strany 19

215.1.1 THETESTINDICATORThe green Test LED is the LED closer to the LOOP switch. It lights toindicate that V.52 or V.54 tests are running.5.1.2 THEERR

Strany 20

22MULTI-FUNCTION LINE DRIVER5.3.1 LOCALANALOGLOOPBACK(LAL)The Local Analog Loopback (LAL) test checks the operation of the localMulti-Function Line Dr

Strany 21

235.3.2 REMOTEDIGITALLOOPBACK(RDL)The Remote Digital Loopback (RDL) test checks the performance of both thelocal and remote Multi-Function Line Driver

Strany 22

24MULTI-FUNCTION LINE DRIVER5.3.3 USING THEV.52 BERT TESTINDEPENDENTLYThe Multi-Function Line Driver can perform its V.52 BERT test independentlyof th

Strany 23 - 4.2 RS-232 Serial Connections

MULTI-FUNCTION LINE DRIVERNORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENTINSTRUCCIONES DE SEGURIDAD1. Todas las instrucciones de segurida

Strany 24

25CHAPTER 6: Troubleshooting6.1 Calling Black BoxIf you determine that your Multi-Function Line Driver is malfunctioning, do not attempt to alter or r

Strany 25 - 5.1 Status LEDs

26MULTI-FUNCTION LINE DRIVERThe Multi-Function Line Driver has been performance-tested using twisted-pair cable with these characteristics:Wire Gauge

Strany 26 - 5.2 Test Switches

27APPENDIX A: Cable RecommendationsTo gain optimum performance from the Multi-Function Line Driver, pleasekeep these guidelines in mind:• Always use t

Strany 27

28MULTI-FUNCTION LINE DRIVERAppendix B: Block Diagram

Strany 28

1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746© Copyright 1995. Black Box Corporation. All rights reserved.

Strany 29

NOM STATEMENT11. El aparato eléctrico deberá ser connectado a una fuente de poder sólodel tipo descrito en el instructivo de operación, o como se indi

Strany 30 - 6. Troubleshooting

MULTI-FUNCTION LINE DRIVERContentsChapter Page1. Specifications ...

Strany 31

1CHAPTER 1: Specifications Cable Required — For modem-to-modem line: Two- or four-wire unconditioned twisted-pair, 19 to 26 AWG (see Appendix A), pinn

Strany 32

2MULTI-FUNCTION LINE DRIVERSurge-ProtectionMethod — Silicon Avalanche DiodesSurge-ResponseTime — 1 psMaximum SurgeProtection — 600 watts dissipated af

Strany 33 - Appendix B: Block Diagram

3CHAPTER 1: Specifications ME659A-M:(1) RJ-45 female for modem-to-modem line,(1) DB25 male for serial connection;ME659A-F:(1) RJ-45 female for modem-t

Strany 34

4MULTI-FUNCTION LINE DRIVER2.1 OverviewThe Multi-Function Line Driver (MFLD) is a carrier-controlled short-rangemodem that requires no AC power or bat